Tel : 0755-86142288#76033
Email : zhangwenying@yankong.com
Brand:
YakoItem no.:
YKD2822MPayment:
100% T/T payment before deliveryProduct origin:
Made in ChinaProduct weight:
0.8kgLead Time:
Confirm the PO, normally 7 workdays.2 Phase Open-Loop Stepper Motor Drive Controller
YKD2822M is high performance digital step drive based on YAKO's new 32-bit DSP technology. It's suitable for 86-130mm(NEMA34-57) 2 phase open-loop stepper motors.
Features:
Application:
Mainly used in CNC machine tools, engraving machines, packaging equipment, woodworking machinery, laser cutting machines, textile equipment, ceramic equipment, electronic equipment constant speed applications.
Dimensions:
YKD2822M Microstep Setting:
YKD2822M Current Setting:
Terminal Introduction:
Symbol |
Function |
Specification |
|||
PWR |
Power indicator |
When power on, the green indicator lights up. When there is a pulse input the green indicator light flashes. |
|||
O.C |
Fault indicator |
When over current, under voltage or over voltage, the red indicator lights up |
|||
PU+24V/5V |
Input signal + (24V/5V) |
Connect to 24V/5V power supply |
|||
PU-
|
SW15=ON, it’s CW pulse signal |
Effects on falling edge, the motor moves a step when pulse goes from high to low. It requires: When connect with 5V PU+, low level 0~0.5V, high level 4~5V; when connect with 24V PU+, low level 0~0.5V, high level 20~24V. Pulse width >2.5us, effective edge can be selected by DP14 in pulse/direction control mode |
|||
SW15=OFF, it’s pulse signal |
|||||
DR+24V/5V |
Input signal + (24V/5V) |
Connect to 24V/5V power supply |
|||
DR- |
SW15=ON, it’s CCW pulse signal |
Effects on falling edge, the motor moves a step when pulse goes from high to low. It requires: When connect with 5V PU+, low level 0~0.5V, high level 4~5V; when connect with 24V PU+, low level 0~0.5V, high level 20~24V. Pulse width >2.5us. |
|||
SW15=OFF, it’s direction control signal |
Used to change motor direction. It requires: When connect with 5V PU+, low level 0~0.5V, high level 4~5V; when connect with 24V PU+, low level 0~0.5V, high level 20~24V. |
||||
MF+24V/5V |
Input signal + (24V/5V) |
Connect to 24V/5V power supply |
|||
MF- |
Motor free signal - |
When effective (low level), the motor coil current is turned off and motor free. |
|||
FL+ |
Fault output signal + |
FL+ connect to the output current limiting resistor |
|||
FL- |
Fault output signal - |
FL- connect to the output GND, maximum drive current 50mA, and maximum voltage 50v. |
|||
TM+/TM- |
Home output signal +/- |
TM+ connect with the resistor, TM- connect to output GND. Maximum drive current 50mA, and maximum voltage 50V. |
|||
AC |
Power supply |
AC110- 220V |
|||
+A,-A |
Motor connection |
|
|||
+B,-B |