Tel : 0755-86142288#76033
Email : zhangwenying@yankong.com
Brand:
YakoItem no.:
YKD3422MPayment:
100% T/T payment before deliveryProduct origin:
Made in ChinaProduct weight:
0.65kgLead Time:
Confirm the PO, normally 7 workdays.YKD3422M 3 Phase Open-Loop Stepper Drive DC20~60V
YKD3422M 3 phase open-loop stepper drive suitable for 42-86mm(NEMA17-34) 3 phase open-loop stepper motors. Mainly used in kinds applications.
Features:
Application:
Mainly used in CNC machine tools, engraving machines, packaging equipment, woodworking machinery, laser cutting machines, textile equipment, ceramic equipment, electronic equipment constant speed applications
Dimensions:
YKD3422M Microstep Setting:
YKD3422M Current Setting:
Terminal Introduction:
Symbol |
Function |
Specification |
PWR |
Power indicator |
When power on, the green indicator lights up. |
O.C |
Fault indicator |
When over current, under voltage or over voltage, the red indicator lights up. |
PU+24V/5V |
Input signal + (24V/5V) |
Connect to 24V/5V power supply |
PU- |
SW15=ON, it’s CW pulse signal |
Effects on falling edge, the motor moves a step when pulse goes from high to low. It requires: When connect with 5V PU+, low level 0~0.5V, high level 4~5V; when connectwith 24V PU+, low level0~0.5V,high level20~24V.Pulse width >2.5us. effective edge can be selected by DP14 in pulse/direction control mode. |
SW15=OFF, it’s pulse signal |
||
DR+24V/5V |
Input signal + (24V/5V) |
Connect to 24V/5V power supply |
DR- |
SW15=ON, it’s CCW pulse signal |
Effects on falling edge, the motor moves a step when pulse goes from high to low. It requires: When connect with 5V PU+, low level 0~0.5V, high level 4~5V; whe connect with 24V PU+, low level 0~0.5V, high level 20~24V. Pulse width >2.5u |
SW15=OFF, it’s direction control signal |
Used to change motor direction. It requires: When connect with 5V PU+, low level 0~0.5V, high level 4~5V; when connect with 24V PU+, low level 0~0.5V, high level 20~24V. |
|
MF+24V/5V |
Input signal + (24V/5V) |
Connect to 24V/5V signal power supply |
MF- |
Motor free signal |
When effective (low level), the motor coil current is turned off and motor free. |
FL+ |
Fault output signal + |
FL+ connect to the output current limiting resistor |
FL- |
Fault output signal - |
FL- connect to the output GND, maximum drive current 50mA, and maximum voltage 50v. |
TM+/TM- |
Home output signal +/- |
TM+ connect with the resistor, TM- connect to output GND. Maximum drive current 50mA, and maximum voltage 50V. |
AC |
Power supply- |
AC110-220V |
U |
Motor connection |
|
V |
||
W |